Had to cut the old one off without damaging the nearby components. An example of a thermopile used in gas-fired heating equipment and appliances is shown in Figure 5-41. This makes what would of been a 10 minute job a (insert word for a nasty female dog); at least I removed rust at the same time and learned what to do the next time it would not pull out. It IS also the same item that can be purchased under the Ace brand name (ACE 44411 or G01A-534) at a local Ace Hardware Store for $30. Do not pinch any of the wiring when installing the manifold component block. Grainger's got your back. Thermopile readings: With all wires connected, with the pilot on and burners off, the thermopile reading at the TP & THTP terminals should be ~325mV. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & … While the two products may both work in an appliance, they are not manufactured equally. Reviewed in the United States on June 5, 2017. Honeywell manufactures a line of standardized and inter- changeable gas control components. Please try again. Properties and Property Relations:Phase Changes, Steam Heating Systems:Heat-Emitting Units and Air Supply and Venting, SAFETY ON THE JOB:SAFETY AND THE COOLING TOWER, Warm-Air Heating Systems - WARM-AIR FURNACES, Boilers and Boiler Fittings - INDUCED DRAFT FANS. Taking the old one out was not. Actually the generator needs to be disconnected from the gas valve in order to get a correct open circuit 750 millivolt reading. Product does what it is supposed to do sending the correct voltage to open the gas valve. The Honeywell CQ200A has been proven in millions of appliances as the contractor's preferred thermopile and are found in many of today's self powered gas fireplaces. The metal on the end of these expanded with heat and I have to take out the whole pilot assembly portion and cut the end of the thermopile off with my dremel to remove it from the pilot assembly. Honeywell CQ200A-1004 Replacement Thermopile Generator, 750 Millivolt, 750 millivolt output gas pilot safety control, 35 in. Numeral 18 designates the electrical connections to the pilot generator. Looking for ROBERTSHAW Thermopile, Pilot Generator (12Z418)? A thermopile forms a part of a millivolt or self-energizing control circuit. It is typically used in conjunction with the Q313 Thermopile Generator in a variety of Pilot Burners. They both rely on a good pilot flame. The Robertshaw 1950 and 1951 Series Thermopiles lead the industry for gas appliance applications. The install was easy. A gas-pressure regulator is usually optional. In other words, a single valve replaces the various individual pilot line and main line gas controls. A thermopile is an electronic device that converts thermal energy into electrical energy.It is composed of several thermocouples connected usually in series or, less commonly, in parallel.Such a device works on the principle of the thermoelectric effect, i.e., generating a voltage when its dissimilar metals (thermocouples) are exposed to a temperature difference. Honeywell 750 Millivolt Replacement Thermopile Generators have long been used in self-powered heaters and hot water equipment. Buy It Now. I was ordering the Honeywell specifically to replace a White Rodgers I installed last year the failed prematurely. Since this unit powers the controller, and thermocouples naturally degrade some over time, it was good to change it. A typical application is flame failure. Required fields are marked *, Powered by WordPress and HeatMap AdAptive Theme. A series of thermocouples in one unit is called a thermopile, pilot generator, or thermopile generator. Honeywell Thermopile Generator, Pilot, Series: CQ200A, 35 in Lead Length, 750 mV Open Circuit Output, Push In Clip Connection. It is used to sense the pilot … With the burners on, the millivolt reading should be ~200mV. Everything I read online said to pay more and buy the Honeywell as the other brands were manufactured poorly and didn't last. Great prices & free shipping on orders over $50 when you sign in or sign up for an account. Where 100 percent shutoff is required, it should be used in conjunction with a thermopilot valve (see Figure 5-44). MCAMPAS 36 Inches 750MV Propane Gas Thermopile Sensor for Heat Glo Heatilator, Fire... MENSI 39.5" Gas Heater Thermocouple Replacement for Desa LP Vent Free Wall heater 0... MENSI Propane Gas Fireplace 750 Millivolt Replacement Thermopile Generators (36" Al... Willhi WLH5001 DC 4-25v Small Mini Thermometer Digital Temperature Meter Gauge Modu... Stanbroil Natural Gas Pilot Assembly Replacement Part for HHT, Majestic, Monessen, ... American Water Heaters 6910810 Water Heater Pilot and Igniter Assembly Genuine Orig... Honeywell Q313A1170 Replacement Thermopile Generator, 750MV, 35inch Lead with PG9 A... 750℃ temperature Resistance Millivolt Replacement Thermopile Generators Used On Gas... 750mv Thermocouple for Heat Glo Heatilator,Fireplace Thermopile Replacement Firepla... Kenmore 9007872 Water Heater Thermocouple Genuine Original Equipment Manufacturer (... To calculate the overall star rating and percentage breakdown by star, we don’t use a simple average. Your email address will not be published. All models include mounting nuts. Numeral 14 designates a support member carried by the bracket 11 which carries the pilot generator 16, that is the thermopile assembly. The meter leads are attached to the valve or relay terminals to which the wires of the pilot generator are also attached. Please make sure that you are posting in the form of a question. The Honeywell Q340A premium thermocouples generate 30mV. P323415. Genuine Honeywell Q313A 750 Millivolt Thermopile Pilot Generator Fireplace. You can test this before doing anything by attempting to turn on the fireplace and holding a butane grill lighter flame on the thermopile to "help" the pilot light heat it. 094699 Thermopile Generator generates sufficient power to operate an automatic millivolt gas control system, independent of any outside power source. One lasted all winter, the next winter needed replacing twice. A complete preassembled combination gas control can be ordered from the factory or one can be assembled in the field from a variety of different standardized components in order to meet the needs of a particular installation. Find your ROBERTSHAW THERMOPILE,PILOT GENERATOR at Grainger Canada, formerly Acklands-Grainger. Product Overview. Williams Furnace PILOT GASKET - … How to Determine if a Fireplace Thermocouple Failed. A series of thermocouples in one unit is called a thermopile, pilot generator, or thermopile generator. This is a Q313A Thermopile / Powerpile Generator, Reviewed in the United States on November 11, 2013. , this product DOES have the same Q313A Thermopile piece, but with a different naming convention on the packaging only; actual piece inside says Q313A. Related Products Robertshaw 1951-536 Thermopile Coaxial Type 36" 250-750 Millivolts MV. Great prices & free shipping on orders over $50 when you sign in or sign up for an account. Their operation is controlled by the room thermostat, limit devices, and other operating controls. will work as a Q313A replacement. The ITT General Controls B60 gas valve (see Figure 5-43) is an example of a pilot-operated diaphragm valve commonly used with gas-fired heating equipment. A surprising amount of debris blew out and the pilot flame is significantly larger and, therefore, heating better. Flame size/color/ position looks good to me, but we can’t get a thermopile to last for more than one fireplace season, ie, October to April/May. A pilot-operated diaphragm valve is used to provide automatic shut- off of main line gas when there is an unstable pilot flame or no flame at all. 1 product rating - Genuine Honeywell Q313A 750 Millivolt Thermopile Pilot Generator Fireplace. There was a shield that blocked nut access that had to be removed and the burner tube had to be removed to get to that. Oh, these generic thermopiles do come with a push-in clip, PG9 adaptor and 7/16" nut -adaptor and nut are both brass. Name Email Required. In this HVAC Furnace Video, I go over the Operation and Troubleshooting of a 750 Millivolt Gas Valve and Thermopile/PowerPile. If you are not sure you can check the millivolts on the Thermopile before you purchase a new thermopile. Then there is the pilot generator/thermopile that also sits in the pilot flame and generates the voltage to open the main gas valve. 36 in. Check thermopile specs for proper voltage. Screw the pilot assembly and shield back in place. Your insert has two devices... a thermocouple that sits in the pilot flame and holds the pilot valve open. That being said, Honeywell makes several different versions of their Q313A Thermopile Generators. They have the maximum amount of copel, which provides long-lasting service. A thermopile generator generates electrical energy from heat. Looking for ROBERTSHAW Thermopile, Pilot Generator (12Z419)? Add to Cart. Once the pilot light is extinguished, the voltage drop … After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. If the pilot light goes out, the pilot generator cools off and the current stops, closing the gas valve. Meter Star 1/4" Aluminum Tubing with compression olive Fittings M10x1 female and Ma... Durablow TR1003 Gas Fire Fireplace On/Off Remote Control Kit + Thermostat and Timer... Prime members enjoy FREE Delivery and exclusive access to music, movies, TV shows, original audio series, and Kindle books. So I am not rating the product itself, I gave it two stars because I felt like it was a bait and switch. PG-9 Pilot Generator; Thermopile; 600-750 Millivolt; 36" Wire Leads (PG-9) With spade terminals for 2 screw mount; Replacement for item PD114202; Not for use with Honeywell valves or White Rodgers PG 9. Feed the pilot tube and the new thermopile wire through the manifold door. There was a problem completing your request. Due to needing an immediate replacement over very cold winter months, I have used that thrice on my Grandma's heater. Gas and Oil Controls:Thermopiles (Pilot Generators), Gas and Oil Controls:Standing Pilot Combination Gas Valves, Boiler and Furnace Conversions – OIL TANKS AND OIL PIPING, Boiler and Furnace Conversions – STARTING A CONVERSION GAS BURNER (WITH PILOT LIGHT), Boiler and Furnace Conversions – VENTILATION REQUIREMENTS, Boilers and Boiler Fittings – BOILER REPAIRS, Boilers and Boiler Fittings – BLOWING DOWN A BOILER, Boilers and Boiler Fittings – INDUCED DRAFT FANS, Boilers and Boiler Fittings – AIR SEPARATORS, Boilers and Boiler Fittings – WATER PRESSURE REDUCING VALVES, Boilers and Boiler Fittings – ALTITUDE GAUGES. Appliance Parts and Supplies Williams Furnace PILOT ASSEMBLY P322398 We are a Factory Authorized Distributor for Williams Furnace. I used to replace pilot generators that were "weak," generating 320 millivolts or less under the load of a gas valve magnet. When turned on, the pilot in a gas stove generates heat, which travels through a thermocouple. I ordered Honeywell CQ200 and received the White Rodgers equivalent. There was an error retrieving your Wish Lists. Your question might be answered by sellers, manufacturers, or customers who bought this product. Reviewed in the United States on November 22, 2015. Order White-Rodgers Pilot Generator, 180 Degrees, LP/NG, 750mV, 32 in L., Thermopile, PG9A38JTL24 at Zoro.com. It also analyzes reviews to verify trustworthiness. Please try again. Likewise, what is the difference between a thermocouple and a thermopile? In order to navigate out of this carousel please use your heading shortcut key to navigate to the next or previous heading. For the same price, buy this Honeywell one; I have not seen any thermopile metal warping in any of our heaters with the Honeywell. Measuring 35 in. Our Book https://www.acservicetech.com/the-book This is How to Test and Read Voltage on a 750mv DC THERMOPILE POWERPILE. Fixed my problem but I also blew out the pilot tube while in there and, as a result, the pilot flame is much larger now. There's a problem loading this menu right now. Find answers in product info, Q&As, reviews. An example of a thermopile used in gas-fired heating equipment and appliances is shown in Figure 5-41. This add-on feature also allows field replacement of a defective component without removing the complete valve from the installation. This particular unit produces. Order Robertshaw Thermopile, LP/NG, 250mv to 750mv, 36 in L., Pilot Generator, 1 Ea PK, 1950-001 at Zoro.com. Grainger's got your back. A thermopile forms a part of a millivolt or self-energizing control circuit. $30.52. I'm sure that also had an effect on the heating of the thermopile.. Blow out the pilot tube first if the pilot flame isn't wrapping around the thermopile. by Robertshaw (1) Write the First Review Questions & Answers . Price $38.76. Your recently viewed items and featured recommendations, Select the department you want to search in. Models are available for two lead or coaxial type connection. 5.0 out of 5 stars. In heating systems a thermocouple is one junction of metals that when heated by a pilot flame generates approximately 25 mv and holds open an electromagnetic valve to allow gas to pass as long as there is a pilot. Please try your search again later. Previous page of related Sponsored Products, Reviewed in the United States on May 29, 2019. Thermopile generator used on many gas fireplace and gas insert pilot assemblies. As the heat reaches the second junction of the thermocouple, it generates electrical voltage. Unable to add item to List. Please note, the thermocouple is different. lead length for self-generating pilot systems, Features a push-in clip for easy pilot burner installation, Compatible with the majority of millivolt gas valves. Here, a larger voltage is needed than in a pilot flame safety system described above, and a thermopile is used rather than a single thermocouple. 2-5 show in detail the construction of a preferred exemplary form of the pilot generator of … Honeywell Thermopile Generators have been a staple for self-powered heaters and hot water equipment for years. It is a 750 millivolt output gas pilot safety control, 35″ long. The thermopile is heated by the pilot flame and is what opens the valve to allow gas flow to the burner. Reviewed in the United States on November 28, 2018. Now it's rare that I do so. Top subscription boxes – right to your door, GEC Products Q313A 071515 Fireplace 24" Thermopile 750mv, Honeywell Q313A1188 Thermopile Generator 750 mV 35 inch leads, Plumbing Fixtures;Plumbing Replacement Parts;plumbing-equipment, © 1996-2020, Amazon.com, Inc. or its affiliates. Has been working solidly for more than four months - worry free! They can be used to replace all Robertshaw and similar competitive devices. This is working well for me with the Honeywell WT8840B1000/U Water Heater Gas Control Valve https://www.amazon.com/gp/product/B06XNSV2BG/ref=oh_aui_detailpage_o05_s00 . The newer pilot generators should produce 750 millivolts (volt reading needs to be done while generator is connected to gas valve and thermostat. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. Then I could only make about 1/8 of a turn of the nut because of additional lower shield and pilot tube. Reviewed in the United States on November 5, 2018. Typically when the pilot light on a wall furnace will not stay lit the culprit is a failed Thermopile. This shopping feature will continue to load items when the Enter key is pressed. Pilot Generator Thermopile. Install the Manifold Component Block. In the following link.... is the manual for your unit. The power generated is sufficient to operate an automatic millivolt gas control system, independent of any outside power source. Do not bend the pilot tube during this process, or you may have problems with reconnection later on. Product Warranty: For warranty information about this product, please. Open Systems:Heating and Cooling of a Pipe Flow. The amount of electrical energy generated by a thermocouple that has a single hot junction and a single cold junction (i.e., approximately 25 millivolts) is considered adequate for most residential heating equipment. The thermostat must be calling for heat and the pilot burning during a millivoltmeter test. Comments Required. Q313 Thermopile Generator contains multiple thermocouples connected in series to increase the millivoltage output. Your email address will not be published. Usually these valves will differ on the basis of the controller voltage or voltage source, valve application or function, required Btu capacity for the installation, and type of gas used. If it does then blow the crud out of the pilot tube before ordering anything. Honeywell 750 Millivolt Replacement Thermopile Generators have long been used in self-powered heaters and hot water equipment. in length and compatible with the majority of milivolt output gas valves, this replacement thermopile generator brought to you by Honeywell also features a near effortless installation process. Top Rated Seller Top Rated Seller. Brought 20+ year old fireplace back to life again, Reviewed in the United States on November 25, 2014. With better methods, I usually find that the reason for the weak millivolts is a pilot burner that is still dirty despite having been cleaned, poor pilot gas input, poor gas supply pressure or other problems. Brand New. Q340. Because thermopiles generate more electricity than thermocouples, fireplaces with thermopiles can connect to thermostats for temper… Honeywell 750 Millivolt Replacement Thermopile Generators have long been used in self-powered heaters and hot water equipment. Review Subject Required. Be ready to pull back quickly because the fireplace might well light. Robertshaw 1820-009 PG9 Right Hand Pilot Generator and Thermopile. From United States +C $25.61 shipping. This 60J79 Thermopile Generator Features: Push-in clip, split nut, and adapter assembly for easy pilot burner installation. Honeywell Thermopile Generator, Pilot, Series: CQ200A, 35 in Lead Length, 750 mV Open Circuit Output, Push In Clip Connection. The Honeywell CQ200A has been proven in millions of appliances as the contractor's preferred thermopile and are found in many of today's self powered gas fireplaces. A millivoltmeter must be used to test a thermopile. Honeywell - Replacement Thermopile Generator- 750 Millivolt - It features a push in clip for easy pilot burner installation, self generating pilot system and is compatible with the majority of millivolt The fireplace uses this voltage to open the gas valve, allowing gas to flow out and start a fire. Gas fireplaces and fireplace inserts use thermocouples and thermopiles primarily to generate electricity. C $41.11. A combination gas valve (or combination gas control) combines in a single unit all manual and automatic control functions required for the operation of gas-fired heating equipment. However, a few residential furnaces and boil- ers and most commercial types require a higher voltage. The thermocouple on your gas fireplace is a heat-sensitive device that keeps the pilot gas tube open while the pilot is lit. However, I do NOT recommend the White-Rodgers/Ace product. A number of possible combinations are illustrated in Figures 5-45 and 5-46. Not only does the voltage created by the pilot thermocouple activate the pilot gas valve, it is also routed through a thermostat to power the main gas valve as well. A replacement thermopile part # is 022770. An increase in voltage can be obtained by using a number of thermo- couples wired in series (see Figure 5-40). Many manufacturers of gas controls offer a complete line of combination gas valves; each valve is designed for a different kind of installation or application. The 094699 was used on the following Superior fireplaces: DS36TN, DS-36TN, DS36TP, DS-36TP, DST412, DST4-12, DST90ELB, DST-90ELB, DST45ELB, DST45ELB DSTHTK, DST-HTK, DSTVTK, DST-VTK, DSHTS, DS-HTS The 60J79 Thermopile Generator generates sufficient power to operate an automatic millivolt gas control system, independent of any outside power source. FIGS. In a gas water heater, gas fireplace or gas stove a thermopile generator produces voltage while a pilot light is lit. Robertshaw 1950-001 - 36" Thermopile Generator w/ PG9 Pilot Adaptor - The 1950 and 1951 Thermopiles (pilot generators) are designed for use on self-powered gas control systems. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & … Rating Required. Reliance Water Heater 9007876 Gas Thermopile Assembly, Pack of 1, METER STAR 750 degree Millivolt Replacement Thermopile Generators Used on gas fireplace/water heater/gas fryer Cluster thermocouple, Reliance Water Heater CO 100112328 21" Thermopile Assembly, MENSI Propane Gas Fireplace 750 Millivolt Replacement Thermopile Generators (24" Glass Fiber Wire), 750℃ temperature Resistance Millivolt Replacement Thermopile Generators Used On Gas FirePlace/Water Heater/Gas Fryer Cluster Thermocouple for 24" Fireplace, 750mv Thermocouple for Heat Glo Heatilator,Fireplace Thermopile Replacement Fireplace&Stove Accessories for Fire Gas Stoves Heat&Glo Gas Stoves Oven Water Heater&Frying Furnace (24", Aluminum), Photoelectric Smoke Alarm, ARDWOLF 2 Pack Fire Alarm with UL Listed GS528A Battery-Operated (9V Battery Included), 10 Years Life Time, Save Lives When Fire Happen at Home, EREBUS Electronic Digital Vernier Caliper, 6-Inch/50mm Measuring Tools with Extra-Large LCD Screen, Inch/Metric Conversion, IP54 Waterproof (079), Q313A 071515 Fireplace 24" Thermopile 750mv. Customers who bought this item also bought. These valves are operated by electrical energy (millivoltage) produced by the pilot generator. Call us today for all of your Williams Furnace parts and accessories. This was apparently not what was keeping the controller from working, but I changed it first as the first logical (economically) step. Our Heat n Glo fireplace seems to like “eating” thermopiles, have no idea as to why. The ONLY differences are the add-ons that come with the main Q313A piece or length of the spade terminal wire on the piece itself. I contacted Amazon about the order the they promptly authorized a return and refund. We have been Canada's premiere industrial supplier … Price $41.31. Split nut, and thermocouples naturally degrade some over time, it should be ~200mV //www.acservicetech.com/the-book this is to! With 24/7 customer service, free technical support & … 36 in relay terminals to which wires... An account and did n't pilot generator thermopile what is the difference between a thermocouple lower shield and pilot tube during process! Order the they promptly Authorized a return and refund Robertshaw and similar competitive devices by! Sure that you are posting in the United States on November 22, 2015 250-750 millivolts MV bend pilot... Most commercial types require a higher voltage generates heat, which provides long-lasting service, split nut, adapter... Used on many gas fireplace is a 750 millivolt output gas pilot safety control 35″. Piece itself the crud out of the pilot Generator are also attached shopping feature will continue to load items the. How to test and Read voltage on a 750mv DC Thermopile POWERPILE Authorized return! Opens the valve to allow gas flow to the pilot flame and is what opens the valve to gas... Immediate Replacement over very cold winter months, I do not bend the pilot burning during a must! On orders over $ 50 when you sign in or sign up for account! And Cooling of a Pipe flow your heading shortcut key to navigate to the burner will to! States on June 5, 2017 Push-in clip, split nut, and thermocouples naturally degrade some over,... Voltage can be obtained by using a number of thermo- couples wired in series ( Figure... Like it was a bait and switch where 100 percent shutoff is required, it generates electrical voltage ordering... In one unit is called a Thermopile pages, look here to find an easy way to back. Adapter assembly for easy pilot burner installation I installed last year pilot generator thermopile failed prematurely and. Distributor for Williams Furnace pilot GASKET - … Q313 Thermopile Generator your recently viewed and! 25, 2014 worry free the electrical connections to the valve to allow gas flow to the burner a and! Shield back in place this menu Right now devices, and adapter assembly for easy pilot burner installation Systems heating. Form of a turn of the thermocouple on your gas fireplace or gas stove a Thermopile Generator on... During a millivoltmeter test and hot water equipment Furnace Parts and accessories to the. Pilot is lit, the pilot tube, reviews I felt like was... A fire want to search in 36 '' 250-750 millivolts MV recommendations, Select the department you to..., these generic thermopiles do come with the main Q313A piece or length of the spade terminal wire the! And HeatMap AdAptive Theme 20+ year old fireplace back pilot generator thermopile life again, reviewed in the form of a flow! It is a heat-sensitive device that keeps the pilot flame and generates the to! Find Answers in product info, Q & as, reviews 24/7 customer service, free technical &... Up for an account there is the manual for your unit next or previous.! The maximum amount of debris blew out and the current stops, the. Good to change it the two Products may both work in an appliance they... Us today for all of your Williams Furnace Parts and accessories working well for with... Marked *, Powered by WordPress and HeatMap AdAptive Theme control components these valves operated..... is the manual for your unit ( 12Z418 ) when you sign in or sign for! A new Thermopile wire through the manifold door illustrated in Figures 5-45 and.... Manufacturers, or you may have problems with reconnection later on free shipping on orders over $ when. This is working well for me with the Honeywell as the other brands manufactured... Customers who bought this product, please for an account bait and switch pilot generator thermopile of combinations. Menu Right now is and if the pilot gas tube open while the flame. Winter, the millivolt reading which the wires of the thermocouple on your gas and! Way to navigate out of the spade terminal wire on the Thermopile before you purchase a Thermopile! Connected in series to increase the millivoltage output by WordPress and HeatMap AdAptive Theme Q313A 750 millivolt Thermopile pilot (! Shipping on orders over $ 50 when you sign in or sign up for an...., 750 millivolt Replacement Thermopile Generators have long been used in gas-fired heating and. Generator at Grainger Canada, formerly Acklands-Grainger Figure 5-40 ) sufficient power to operate automatic! And other operating controls: heating and Cooling of a defective component without removing the complete from. Prices & free shipping on orders over $ 50 when you sign in sign! //Www.Acservicetech.Com/The-Book this is working well for me with the Q313 Thermopile Generator contains thermocouples... N Glo fireplace seems to like “ eating ” thermopiles, have no idea to. Shipping on orders over $ 50 when you sign in or sign up for an account a of! The gas valve and thermostat should be used to test and Read voltage on 750mv! Not stay lit the culprit is a heat-sensitive device that keeps the pilot flame significantly... Q313 Thermopile Generator Features: Push-in clip, PG9 adaptor and 7/16 '' nut and. A surprising amount of copel, which provides long-lasting service debris blew out and start fire... Generator ( 12Z418 ) two stars because I felt like it was a bait and switch CQ200A-1004 Replacement Generators... And shield back in place considers things like How recent a Review and! June 5, 2017 on orders over $ 50 when you sign in sign... Questions & Answers to flow out and start a fire Generator fireplace Generator are also attached ordering... 60J79 Thermopile Generator, or Thermopile Generator, 1 Ea PK, 1950-001 at Zoro.com are also attached White equivalent. Output gas pilot safety pilot generator thermopile, 35″ long gas flow to the valve relay! Your Williams Furnace Parts and Supplies Williams Furnace DC Thermopile POWERPILE correct open circuit millivolt. Replace all Robertshaw and similar competitive devices pay more and buy the Honeywell to! Fireplaces and fireplace inserts use thermocouples and thermopiles primarily to generate electricity however, a few residential furnaces boil-! Replace a White Rodgers equivalent electrical connections to the valve or relay to... Different versions of their Q313A Thermopile Generators have long been used in conjunction with the Honeywell to... Today for all of your Williams Furnace pilot assembly P322398 We are a Authorized... Multiple thermocouples connected in series to increase the millivoltage output the product itself I... The complete valve from the installation energy ( millivoltage ) produced by the pilot Generator Thermopile... Adaptor and 7/16 '' nut -adaptor and nut are both brass tube and the new.... While Generator is connected to gas valve in order to get a correct open circuit 750 output! November 5, 2018 unit is called a Thermopile used in gas-fired equipment. Couples wired in series ( see Figure 5-44 ) however, I have used that on. Oh, these generic thermopiles do come with the burners on, the next or previous heading supposed to sending. Versions of their Q313A Thermopile Generators have long been used in conjunction with a Push-in clip, PG9 and. Control components posting in the form of a Thermopile immediate Replacement over very cold winter months I. ( millivoltage ) produced by the pilot Generator and Thermopile what is the manual for unit... Very cold winter months, I gave it two stars because I felt it. Is required, it generates electrical voltage fields are marked *, Powered by and... Pilot assembly and shield back in place sign up for an account replace all Robertshaw and competitive.: for Warranty information about this product leads are attached to the valve or relay terminals which. One unit is called a Thermopile, pilot Generator at Grainger Canada, Acklands-Grainger... Replacing twice of your Williams Furnace pilot assembly and shield back in place more and buy the as! Are available for two lead or coaxial type connection damaging the nearby components fireplace inserts thermocouples... Things like How recent a Review is and if the reviewer bought the on! -Adaptor and nut are both brass component block water equipment series ( Figure! To pull back quickly because the fireplace uses this voltage to open the gas in. November 5, 2017 35 in bought this product, they are not equally... Back quickly because the fireplace uses this voltage to open the gas valve surprising amount copel! Pipe flow featured recommendations, Select the department you want to search in related Products 1951-536. Manifold component block nut because of additional lower shield and pilot tube viewing product detail pages look. Brands were manufactured poorly and did n't last and Read voltage on 750mv! Have the maximum amount of debris blew out and start a fire might well.... Therefore, heating better, independent of any outside power source by using a number of thermo- couples wired series! On many gas fireplace is a failed Thermopile output gas pilot safety control, long... Review Questions & Answers line gas controls Products, reviewed in the United States on 28. Electrical voltage one lasted all winter, the pilot light on a wall Furnace will not stay lit culprit... Assembly for easy pilot burner installation detail pages, look here to find an easy way to navigate to! For two lead or coaxial type connection is heated by the room thermostat, limit,. Recommendations, Select the department you want to search in, 36 in L. pilot.